Boxes of Energy Flo J Type, Energy Flo Peace Style Classic and SMC acupuncture needles on a wooden tabletop beside the title How to Choose Acupuncture Needles

Choose acupuncture needles by the millimeters on the label, not the gauge number, the inch size or the handle color, because makers don't line those up the same way. Then pick the handle for the job (metal for warm needling and electroacupuncture), decide whether you want one needle per guide tube or ten per blister, and trial a 100-count box before you buy a bulk size.

My father, Gary, started Acu-Market® in 2001. In the early 2000s he became the exclusive U.S. importer of Peace needles and pushed the factory to machine-made precision. Here is how I'd read a needle listing, with every spec taken from our listings, the Clean Needle Technique (CNT) Manual (CCAHM, 7th ed., revised May 11, 2026) or the manufacturer's federal device records.

What do the gauge numbers and colors mean?

Our listings give the Chinese gauge, the diameter in millimeters and a handle color for each size. The Japanese column is Seirin's numbering, taken from the records Seirin Corporation files in the FDA's Global Unique Device Identification Database (GUDID).

Diameter Chinese gauge Japanese No. (Seirin GUDID) Color on our listings
0.10mm 46 03 Dark Blue
0.12mm 44 02 Dark Green
0.14mm 42 01 Lime Green
0.16mm 40 1 Red
0.18mm 38 2 Ivory
0.20mm 36 3 Blue
0.22mm 34 — (Seirin files none) Pink
0.23mm 34 4 Pink (Seirin)
0.25mm 32 5 Purple
0.30mm 30 8 Brown
0.35mm 28 10 Gray

Two things trip people up. First, the Japanese numbers turn around at the fine end: past No. 1 they run 01, 02, 03, so a 03 (0.10mm) is thinner than a 01 (0.14mm). Second, pink is two sizes. Most size charts, including the older table on our own size chart page, put Japanese No. 4 at 0.22mm. Seirin's own GUDID records file No. 4 as 0.23mm (for example, this J-Type 0.23 x 30mm record). Every other pink needle in our Acupuncture Needles collection is 0.22mm, and both are sold as 34 gauge. If you move a patient between brands at this size, go by the millimeters.

For lengths, keep our acupuncture needle size chart open in another tab; go by this post for No. 4.

Is a 1-inch needle 25mm or 30mm?

Both, depending on the brand. Inch labels are rounded, and they hide a 5mm difference. On our listings:

  • 1" = 25mm: Peace Classic, Peace VALUE-PAK and JUMBO-PAK, Peace Golden-Glyder, and the Mac Ultra-Smooth coil handle lines (100-count, Eco Pack, Ultra-5).
  • 1" = 30mm: Energy Flo® J Type, Free-Style Pak and Spring 10, SMC, the Mac Pipe Handle, Seirin J Type and DBC Spring Ten.
  • 1/2" = 13mm: Peace Classic, VALUE-PAK and JUMBO-PAK, Mac Ultra-Smooth and Ultra-5, DBC Detox 5.
  • 1/2" = 15mm: Energy Flo, SMC, Peace Golden-Glyder, the Mac Pipe Handle, Seirin and DBC Spring Ten.

The Mac Master Pak lists both 25mm and 30mm as 1", and both 13mm and 15mm as 1/2". Order it by the millimeter.

Length matters for one CNT rule in particular: never insert a needle all the way to the handle (Critical, CNT Manual p. 96). Pick a length that leaves shaft showing at your usual depth.

Which handle should I use for warm needling or electroacupuncture?

Metal for both. The CNT Manual's warm-needle procedure calls for metal-only needles and says not to use plastic-tipped ones, because the plastic may melt (p. 109). For electroacupuncture, it says stainless steel needles are safe with electrical stimulation, that it may be advisable to avoid plastic handles because of diminished conduction, and that silver needles should be avoided (p. 44). Here is what each handle is on our listings:

  • Peace Classic: silver coil with a traditional Chinese loop.
  • Mac Ultra-Smooth: thick, extra-long coil with a smooth top and no loop.
  • SMC and Energy Flo Spring 10: spring-style metal, no loop.
  • Peace Golden-Glyder: spring-style handle, gold plated with the shaft.
  • Mac Pipe Handle: lightweight plated aluminum. The listing says the light handle keeps short needles from leaning after insertion.
  • Energy Flo J Type: ribbed plastic with a rounded top, color-coded by gauge. Fine for plain needling; keep it away from moxa.

For the story behind our three needle lines, Energy Flo, Peace and SMC, see Our Needles.

How does the needle come out of the guide tube?

It changes your insertion motion, so check before you switch. On the Energy Flo J Type, our listing says the handle is laser-welded to the guide tube and a light twist frees it. Our Seirin J Type listing calls its release Light Touch: a gentle press frees the needle, no twist. The Mac Ultra-5 has no individual tubes at all: five needles per blister with the tips held in surgical sponge, and 10 spare tubes in the box.

Three needles on our listings come with no tube at all. The Energy Flo B Type is 15mm, for direct insertion. The Seirin D Type is 15mm, for one-hand insertion. The Mac Pipe Handle Detox needle is 0.20 x 15mm, made for the NADA ear protocol.

One needle per tube, or ten per blister?

The packing changes with box size, and not always where you'd expect. Here is the checklist from our listings:

Box Count Packing
Peace Classic 100 1 needle per tube
Peace VALUE-PAK 500 1 needle per tube
Peace JUMBO-PAK 1,000 10 per blister, 1 shared tube
Energy Flo J Type 100 1 needle per tube
Energy Flo Value-Pak J Type 500 1 needle per tube
Energy Flo Free-Style Pak 100 10 per blister, 1 shared tube
Energy Flo Spring 10 1,000 10 per blister, 1 shared tube
SMC ECO PAK 500 1 needle per tube
SMC Blister Pack 1,000 10 per blister, 1 shared tube
Mac Eco Pack 500 1 needle per tube
Mac Master Pak 1,000 10 per blister, 1 shared tube
Mac Ultra-5 400 5 per blister, 10 spare tubes per box

Every 1,000-count box in our needle collection is ten to a blister. That packing comes with a CNT rule. Once a multi-needle pack is opened for one patient visit, the unused needles are discarded (CNT Manual pp. 17, 79; Critical on p. 96). They are not saved for another patient later that day, or for the same patient on another day. The manual also says multi-needle packs are fine with proper clean technique. So ten per blister works when you use most of the blister on one patient, and wastes needles when you use three.

Coated or uncoated?

Our Peace Classic listing specifies US Dow Corning medical-grade silicone on the tip. If you or a patient want to avoid silicone, two needles are listed without it. The Peace Golden-Glyder is 24K gold plated over 304 stainless steel, with no silicone coating. The Mac Korean Hand & Cosmetic is a 0.16 x 7mm needle listed as silicone-free and pyrogen-free.

How should I test a new needle before buying in bulk?

Order a 100-count box of two or three candidates in the same diameter and length, and use them side by side for a week. Write one line on each: how it went in, how it held, how the handle felt. When one wins, move that size to a 500 or 1,000 box, and keep 100-count boxes for sizes you use rarely. SMC's smallest box on our listings is the 500-count ECO PAK, and Energy Flo Spring 10 comes only as 1,000; call us if you want to try a size first.

Don't buy bulk past what you'll use. The CNT Manual makes checking sterilization expiration dates before use Critical (p. 96) and says to check every needle in the clinic for expiration regularly, monthly for example, and discard expired ones (p. 79). Rotate older boxes to the front.

Every needle above is in Acupuncture Needles.

If you're a licensed practitioner without an account yet, apply for a practitioner account to see practitioner pricing. If you have a question about a gauge or a length, call us. That's what we're here for.

Jason

Family-owned, practitioner-first, since 2001.

We sell to licensed practitioners. Needle selection and technique are the practitioner's clinical judgment; the CNT points above summarize the manual and do not replace it or your state's rules.

Needles, Practice tips
For licensed practitionersApply for a practitioner account

Family-owned, practitioner-first, since 2001.

Frequently asked questions

What do Japanese needle numbers like 01, 02 and 03 mean?

They are Japanese sizes finer than No. 1. In Seirin's own records in the FDA's GUDID device database, No. 1 is 0.16mm, No. 01 is 0.14mm, No. 02 is 0.12mm and No. 03 is 0.10mm. Below No. 1, a bigger number means a thinner needle.

Is Japanese No. 4 the same as a 0.22mm pink needle?

Not in Seirin's records. Seirin files No. 4 as 0.23mm in GUDID, while the other pink needles on our listings are 0.22mm. Both are sold as 34 gauge, so compare the millimeters when you switch brands.

Can I use plastic handle needles for warm needling or electroacupuncture?

Not for warm needling: the CNT Manual's procedure calls for metal-only needles because plastic may melt (7th ed., p. 109). For electroacupuncture, the manual says it may be advisable to avoid plastic handles because of diminished conduction, and that stainless steel needles are safe with electrical stimulation (p. 44).

Can I save the unused needles from an opened ten-needle blister?

No. Once a multi-needle pack is opened for one patient visit, the CNT Manual says the unused needles are discarded, not saved for another patient later that day or for the same patient on another day (7th ed., pp. 17 and 79; Critical on p. 96). Multi-needle packs are fine with proper clean technique; the leftovers are the problem.

Which acupuncture needles come without a guide tube?

On our listings: the Energy Flo B Type (15mm, direct insertion) and the Mac Pipe Handle Detox needle (0.20 x 15mm, for NADA ear work). The Mac Ultra-5 has no individual tubes but includes 10 spare tubes per box.